Electrical installation in general

There is a risk of fatal injuries from touching one or both poles. Conductive objects should never be inserted into the openings of plugs and sockets.

  • Beware of electric arcs within DC-carrying system components!
  • Do not disconnect the cable during operation (disconnect the system from the mains or use a circuit breaker).
  • Beware of moisture during the electrical installation!
    There is a risk of injuries and damage to the system!
    • Roof work should only be performed on dry surfaces.
    • Ensure that the solar panel modules, cables, etc., are dry during the installation.
  • Connect or insulate exposed cable ends.
  • Even when there is little sunlight, the entire open-circuit voltage remains.
  • Even at low temperatures, the maximum permitted system voltage of the solar panel modules must not be exceeded.
  • Adhere to the included installation plan!
  • Higher voltage than protective extra-low voltage!
  • Risk of injury due to the increase in voltage when connected in series!

It is essential to ensure that the electrical installation and commissioning is performed by a licensed electrician.
Depending on national regulations, suitable protective gloves may be required when working with live solar plugs. Particular attention must be paid to checking the gloves for damage before starting work.