Dimensional tolerances

  • 1 = Nominal length
  • 2 = Straightness deviation

Straightness deviation for nominal length [mm] acc. to EN 12020-2 2017 (Table 4)

L ≤ 1,000

0.7

1,000 < L ≤ 2,000

1.3

2,000 < L ≤ 3,000

1.8

3,000 < L ≤ 4,000

2.2

4,000 < L ≤ 5,000

2.6

5,000 < L ≤ 6,000

3.0

L > 6,000

3.5